Consul code analysis wellness.
Press four times 4x the Sleep button on the remote control, and the following error codes appear on the display.
(Operating timer X X X Sleep clear filter)
Access, access, flash off
Failure of the temperature sensor of the outdoor unit heat exchanger. Only products reverse cycle.
Off, off, off, off
Overheat protection. Fan of the outdoor unit automatically shuts down and E2 appear in the product touch panel, because the outdoor unit heat exchanger sensor recorded temperature higher than 53 ° C. off the product and gives 4 bits. While the E2 error appears in the product touch panel, since the outdoor heat exchanger temperature sensor registered greater than or equal to 63 ° C 2 is similar to E43 occurs during reverse cycle.
Access, flash, flash off
E4 = when the speed of the internal fan is less than 200 rpm, E4 will be displayed on the dashboard. All models.
(05) off flashes access off - protection mode IPM ventilation problems.
(06) flashes off off off protection for input AC voltage out of specification (Public voltage is less or greater than the threshold.
off, access off - miscommunication between internal and external unit.
Blinks off access off - overcurrent protection
Off off access off - miscommunication between external unit and cards.
Off off flashes off - failure memory EEPROM of the outdoor unit board.
Access off flashes off - protection for high temperature of exhaust gas by the compressor.
Flashes, access off - short circuit in room temperature sensor, external drive or open circuit detection function or failure.
Access flashes off, off - compressor temperature sensor problems or lack of gas.
Access off access off - protection against freezing or overheating of the evaporator of the indoor unit.
Off access off off - PFC protection is defective (power factor correction).
Access, access, off, off - or flashes access off off - Compressor not part / does not start.
Blinks off access off - rotor protection blocked applicable to the motor of the outdoor unit.
Flashes off off off - Refrigerant gas Excess problem with the fan motor or air flow blockage.
Product problem in two temperature sensors of the indoor unit.
1) Will Flash 10x the code 33
2) Will Flash 10x the code 34