• Supply voltage: 110/220 Volts and 50/60 Hz automatic.
• Switching voltage of the support and pumping outputs: 5 amps
at 220V maximum.
• Consumption: 1 Watt (Solar Control only).
• Measurement range from 0 to 100 ° C.
• Accuracy of +/- 0.3 ° C.
• Sensor type: NTC.
• Number of sensors: three, with capsule and 2m cable.
• Standard 24h real time clock.
• Power outage system for the watch with 24 hours duration.
• Adjustment range for heating temperature control
auxiliary (set1): 10 to 99 ° C.
• Adjustment range for heating temperature differential control
auxiliary (difr): 1 to 15 ° C.
• Adjustment range for controlling the temperature of the collectors (set2): 10 to 99 ° C.
• Adjustment range for controlling the temperature of the pool or thermal reservoir
(set3): 10 to 99 ° C.
• Differential adjustment range for starting the pump (dion): 2 to 15 ° C.
• Differential adjustment range for switching off the pump (diof): 1 to 15 ° C.
• Timer with up to 7 programmable time events combined with the function
thermostat (auxiliary heating).