Contents of the operation command signal (serial signal) from the control of the external unit to the control of the internal unit of the split inverter air conditioner

 The following signals are sent by the control of the external unit.

• The current operating mode.

• Current compressor speeds

• The outside temperature

• The existence of functioning of the protection circuit

To transfer these signals, the control of the indoor unit monitors the contents of the signals and assesses the occurrence of problems.

The contents of the evaluation are described below.

• Whether the current operating conditions are in accordance with the signal from the operating command.

• If the protection circuit is working

When no signal is received from the control of the outdoor unit, a problem is assumed.