Error Codes air conditioner Samsung Inverter

The error code table of the models is reversed in two parts, namely:
The error code table: Internal Unit evaporator - Display digital.
Error code table: external condensing unit - LEDs Yellow, Green and Red.
evaporator Reverse

And about 464 IPM current
E 461 starting error compressor.
E 473 locking error compressor
E 466 error on down the DC voltage LNK
And 221 error from the external temperature sensor.
And exhaust temperature of 416
251 and error discharge temperature sensor
E 468 current sensor error
E 465 error of vlimiti compressor
237 and error coil temperature sensor
E 202 communication 1 min. Sold out
And 458 error fan
E 471 Error OTP
E 467 compressor rotation error
E 440 - E 441 following operating conditions
E 469 - the dc voltage sensor error - link
E 462 Error 1-tri over-current PFC
E 554 refrigerant leak error
And 472 out of the zero crossing of the AC line
And 556 mismatching capacity
E 121 Error environment sensor
E 122 sensor error of the inner coil
And 154 error fan
E 101 comnicação 1 min. Sold out
And 186 error MPI
All lamps flash EPROM error unadjusted data error option
Timer flashing Faulty internal room temperature sensor.
Operation and timer flashing temperature sensor internal coil defective
Turbo flashing malfunction of the internal fan motor
Operation and turbo flashing error of outdoor unit obs power cycle breaker

Defect code table of external condenser unit

Flashing Red on current IPM
Red or green and red accesses abnormal serial communication.
Flashing green starting error compressor
Flashing green and red access normal operation
Green access locking error compressor
Green Access and red flashing error on down DC-LINK voltage.
Yellow and red flashing error of the external temperature sensor
Flashing yellow and red access over-discharge temperature
Yellow and green flashing error discharge temperature sensor
Yellow and green flashing red and access current sensor error
Yellow flashing green access error of vlímite compressor
Yellow and red flashing green access error coil temperature sensor
Flashing yellow and green, red access communication 1min exhausted
Yellow access Fan error
Yellow and red flashing access error of the OTP.
Yellow and red access compressor rotation error
Yellow access and green flashing succession condition only Dual
Yellow green and red flashing access error DC-Link voltage sensor
Yellow and red and green flashing access error I-trip on PFC current
Yellow and green access gas leak error
Yellow and green access, flashing red off the zero crossing of the AC line
Yellow, green, red reset access to connect (1 sec)
Yellow flashing capacity of mismatching
Green and red flashing operation test in cooling mode
Yellow, green, red working test in heating mode