Analysis codes reverse
E1 = operation flashes 1 time, timer off processor error (eepron)
E2 = operation flashes 2 times, timer off voltage signal error.
E3 = operation flashes 3 times off timer evaporator fan error out of control.
E5 = operation flashes 5 times, timer off open room temperature sensor or short.
E6 = operation flashes 6 times, off timer. coil temperature sensor open evaporator.
EC = operation flashes 2 times. Timer access. loss detection or gas leak.
E9 = operation flashes 9 times out timer. Miscommunication between units.
3 Fault in the ambient temperature sensor. Temperature sensor outside the operating range for more than 20 seconds (less than -30 ° C and greater than 100 ° C).
4 sensor failure of the coil of the indoor unit. Temperature sensor outside the operating range for more than 20 seconds (less than -30 ° C and greater than 100 ° C).
8 low voltage failure. The control checks whether the unit is correctly configured for 220Vac.
9 Malfunction of the compressor. If the temperature of the indoor unit coil sensor does not change in a range of + or - 2 ° C during the 5 minute cycle period of the compressor control activates the fault.
10 EEprom failure of the electronic board. If any data is saved incorrectly in the EEprom of the electronic board, the control triggers the failure.
12 address information / zone incorrect unit.
In an installation of several units (through the comfort zone) an address or zone are misconfigured, the control triggers the failure.
Códigos de erro do condicionador de ar Split Carrier inverter
Análise de códigos inverter
E1 = operação pisca 1 vez, timer
apagado erro processador (eepron)
E2 = operação pisca 2 vezes, timer
apagado erro de sinal de tensão.
E3 = operação pisca 3 vezes timer
apagado erro ventilador do evaporador fora de controle.
E5 = operação pisca 5 vezes , timer
apagado sensor de temperatura ambiente aberto ou em curto .
E6 = operação pisca 6 vezes, timer
apagado. Sensor de temperatura de serpentina do evaporador aberto.
EC = operação pisca 2 vezes. Timer
acesso. Detecção de perda ou fuga de gás.
E9 = operação pisca 9 vezes timer
apagado. Falha de comunicação entre as unidades.
3 Falha no sensor de temperatura
ambiente. Sensor de temperatura fora da faixa de operação por mais de 20
segundos (menor que -30°C e maior que 100°C).
4 falha no sensor da serpentina da
unidade interior. Sensor de temperatura fora da faixa de operação por mais de
20 segundos (menor que -30°C e maior que 100°C).
8 falha de baixa tensão. O controle
verifica se a unidade está configurada corretamente para 220Vca.
9 Mal funcionamento do compressor.
Se a temperatura do sensor da serpentina da unidade interna não modificar numa
faixa de + ou - 2°C, durante o período de ciclo de 5 minutos do compressor,
o controle aciona a falha.
10 falha na EEprom da placa
eletrônica. Se algum dado for salvo incorretamente na EEprom da placa
eletrônica, o controle aciona a falha.
12 informação de
endereço / zona da unidade incorretas.
Se em uma
instalação de várias unidades (através do confort zone) algum endereço ou zona
estiverem mal configurados, o controle aciona a falha.
Error Codes air conditioner Split floor ceiling GREE.
E0 = pump defective water
E1 = high pressure control worked or uncalibrated.
E2 = emersion sensor of the evaporator served or uncalibrated.
E3 = low pressure switch worked or uncalibrated.
E4 = the compressor discharge sensor served for high-temperature compressor discharge.
E5 = high current protector of the compressor served.
E6 = communication error between the plates of the evaporator and condenser.
E8 = motor protection evaporator served.
E9 = water pump protection served or is uncalibrated.
F0 = evaporator temperature sensor acted or is out of calibration.
F1 = evaporator immersion sensor acted or is out of calibration.
F2 = emergence of condenser sensor acted or is uncalibrated
F3 = condensing temperature sensor acted or is out of calibration.
F4 = discharge sensor malfunctioning compressor
F5 = ambient sensor defective diplay.
EH = resistance auxiliary heating failed.
FF = micro switch evaporator in wrong or open position.
C5 = jumper Faulty or no capacity on the main PCB.
C1 = protection against arc.
C2 = protection against dispersion of refrigerant.
CF = short-circuit protection
Here are a few checks on the errors below:
E1 = with flashing red LED - indicates that the OVC signal is not reaching the X20 mainboard connector check in condensing the high pressure switch, the relay current and thermal fuses in the connection terminal block. Some of these components is open or opening during operation generating the error.
E2 = with flashing red LED - indicates that the evaporator immersion sensor detected freezing or is out of calibration. To test the sensor using the table 20K sensor bulletin.
E3 = with flashing red LED - indicates that the LPP signal is not reaching the X-19 connector on the motherboard. Check in condensing the low pressure switch it will be open or opening during operation of equipment indicating lack of gas or that it is out of calibration.
E4 = indicates that the immersion sensor connected to the compressor discharge temperature detected high in the refrigerant gas outlet. Check the gas charge and possible obstructions or lack of ventilation in the condenser. The sensor and 50K.
E5 = indicates that there was a power failure for more than 3 seconds or the current reached up to 25 amperes. The plate off the compressor and presents E5 when this occurs 6 times.
red LED flashing indicates that the compressor discharge sensor is loose or uncalibrated. Check the bulletin in 1303 to test its resistance. After some time appear E3 error together.
Temperature sensor shows no error, but the evaporator is only fanning. Check if it is not in trouble by 15K sensor bulletin. The fact display error does not mean that the problem is on the board or in the open component. Lack of gas, dirty condenser, phase failure, bad capacitor, etc. generate these errors. always check the pressure, current, voltage, insufflation and other data before asking for guidance.
E1 = high pressure control worked or uncalibrated.
E2 = emersion sensor of the evaporator served or uncalibrated.
E3 = low pressure switch worked or uncalibrated.
E4 = the compressor discharge sensor served for high-temperature compressor discharge.
E5 = high current protector of the compressor served.
E6 = communication error between the plates of the evaporator and condenser.
E8 = motor protection evaporator served.
E9 = water pump protection served or is uncalibrated.
F0 = evaporator temperature sensor acted or is out of calibration.
F1 = evaporator immersion sensor acted or is out of calibration.
F2 = emergence of condenser sensor acted or is uncalibrated
F3 = condensing temperature sensor acted or is out of calibration.
F4 = discharge sensor malfunctioning compressor
F5 = ambient sensor defective diplay.
EH = resistance auxiliary heating failed.
FF = micro switch evaporator in wrong or open position.
C5 = jumper Faulty or no capacity on the main PCB.
C1 = protection against arc.
C2 = protection against dispersion of refrigerant.
CF = short-circuit protection
Here are a few checks on the errors below:
E1 = with flashing red LED - indicates that the OVC signal is not reaching the X20 mainboard connector check in condensing the high pressure switch, the relay current and thermal fuses in the connection terminal block. Some of these components is open or opening during operation generating the error.
E2 = with flashing red LED - indicates that the evaporator immersion sensor detected freezing or is out of calibration. To test the sensor using the table 20K sensor bulletin.
E3 = with flashing red LED - indicates that the LPP signal is not reaching the X-19 connector on the motherboard. Check in condensing the low pressure switch it will be open or opening during operation of equipment indicating lack of gas or that it is out of calibration.
E4 = indicates that the immersion sensor connected to the compressor discharge temperature detected high in the refrigerant gas outlet. Check the gas charge and possible obstructions or lack of ventilation in the condenser. The sensor and 50K.
E5 = indicates that there was a power failure for more than 3 seconds or the current reached up to 25 amperes. The plate off the compressor and presents E5 when this occurs 6 times.
red LED flashing indicates that the compressor discharge sensor is loose or uncalibrated. Check the bulletin in 1303 to test its resistance. After some time appear E3 error together.
Temperature sensor shows no error, but the evaporator is only fanning. Check if it is not in trouble by 15K sensor bulletin. The fact display error does not mean that the problem is on the board or in the open component. Lack of gas, dirty condenser, phase failure, bad capacitor, etc. generate these errors. always check the pressure, current, voltage, insufflation and other data before asking for guidance.
Códigos de erro do condicionador de ar Split Piso Teto GREE.
E0 = bomba da água avariada
E1 = pressostato de alta pressão
atuou ou descalibrado.
E2 = sensor de emersão da
evaporadora atuou ou descalibrado.
E3 = pressostato de baixa pressão
atuou ou descalibrado.
E4 = sensor de descarga do
compressor atuou por alta temperatura na descarga do compressor.
E5 = protetor de alta corrente do
compressor atuou.
E6 = erro de comunicação entre as
placas da evaporadora e condensadora.
E8 = proteção do motor da
evaporadora atuou.
E9 = proteção da bomba de água atuou
ou está descalibrado.
F0 = sensor de temperatura da
evaporadora atuou ou está descalibrado.
F1 = sensor de imersão da
evaporadora atuou ou está descalibrado.
F2 = sensor emersão da condensadora
atuou ou está descalibrado
F3 = sensor de temperatura da condensadora
atuou ou está descalibrado.
F4 = sensor de descarga do
compressor avariado
F5 = sensor ambiente do diplay
avariado.
EH = resistência auxiliar para
aquecimento avariada.
FF = micro chave da evaporadora em
posição errada ou aberta.
C5 = jumper da capacidade avariado
ou inexistente na PCI principal.
C1 = proteção contra arco voltaico.
C2 = proteção contra dispersão do
fluido refrigerante.
CF = proteção contra curto-circuito
Segue algumas verificações sobre os
erros abaixo:
E1 = com led vermelho piscando –
indica que o sinal OVC não está chegando no conector X20 da placa principal
verificar na condensadora o pressostato de alta, o rele de corrente e os
fusíveis térmicos na borneira de conexão. Alguns destes componentes esta aberto
ou abrindo durante o funcionamento gerando o erro.
E2 = com Led vermelho piscando –
indica que o sensor de imersão da evaporadora detectou congelamento ou está
descalibrado. Para testar o sensor usar a tabela do boletim sensor 20K.
E3 = com LED vermelho piscando –
indica que o sinal LPP não está chegando no conector X-19 da placa principal.
Verificar na condensadora o pressostato de baixa ele estará aberto ou abrindo
durante o funcionamento de equipamento indicando falta de gás ou que o mesmo
está descalibrado.
E4 = indica que o sensor de imersão
conectado na descarga do compressor detectou alta temperatura na saída do gás
refrigerante. Verificar a carga de gás e possíveis obstruções ou falta de ventilação na condensadora. O sensor e o
de 50K.
E5 = indica que ocorreu uma queda
de tensão por mais de 3 seg ou que a corrente chegou até 25 ampéres. A placa
desliga o compressor e apresenta E5 quando isso ocorrer por 6 vezes.
Led vermelho piscando indica que o
sensor de descarga do compressor está solto ou descalibrado. Verificar o
boletim 1303 para testar a resistência do mesmo. Depois algum tempo aparecerá o erro E3 em conjunto.
Sensor de temperatura não apresenta
nenhum erro, mas a evaporadora fica só ventilando. Verificar se o mesmo não
está com problema através do boletim sensor
15K. O fato de apresentar erro não quer dizer que o problema está na
placa ou no componente aberto. Falta de gás, condensador sujo, falta de fase,
capacitor ruim, etc. geram esses erros. Verifiquem sempre as pressões, a
corrente, a tensão, o insuflamento e demais dados antes de pedir orientação.
Error Codes air conditioner GREE Split
code analysis and reverse ON OFF
E2 = 2x operation, evaporator 3x yellow, condenser anti-freeze protection.
E3 = 3x operation, evaporator 9x red, condenser system blocked or leaking coolant.
E4 = 4x operation, yellow 7x evaporator, compressor condenser protected by high temperature
E5 = 5x operation, yellow 5x evaporator, condenser protection AC high current
E6 = 6x operation, green evaporator, condenser OFF: communication failure between pcs. Internal and external drive.
E8 = 8x operation, evaporator 6x yellow, condenser protection against high temperature
H4 = 4x heating. Evaporator 6x yellow capacitor protection against high temperature
H6 = 11x operation, evaporator without response from the indoor unit fan motor.
C5 = 15x operation, Evaporator: CIP jumper faulty or missing
LP = 19x operation, evaporator condenser 16x yellow: Internal and external drive does not match.
L3 = 23x operation, 14x red evaporator condenser malfunction in the external DC fan motor.
L9 = 20x operation, 9x yellow evaporator condenser: power protection.
F0 = 1x operation, 1x evaporator cooling, evaporator: collecting soda.
F1 = 1x cooling, evaporator: the problem of indoor sensor.
F2 = 2x cooling, evaporator: immersion sensor evaporator problem
F3 = 3x cooling, evaporator condenser 6x red: external environment sensor problem.
F4 = 4x cooling, 5x red evaporator condenser: immersion sensor condenser problem.
F5 = 5X cooling, 7x red evaporator condenser condenser temperature sensor problem.
F6 = 6x cooling, 3x red evaporator condenser: limit load on frequency drop.
F8 = 8x cooling, 1x red evaporator condenser: high current limit frequency drop.
F9 = 9x cooling, 2x red evaporator condenser: high temperature often fall outside air.
FH = 2x cooling, heating 2x evaporator, red evaporator 4x anti-freeze down frequency condenser.
H1 = 1x heating, 2x yellow evaporator condenser: Thawing
H3 = 3x heating, 8x yellow evaporator condenser: compressor overload protection.
H5 = 5x heating, evaporator 4x yellow Condenser protection IPM.9
H5 = 5x heating, 10x yellow evaporator condenser: very high temperature module.
HC = 6x heating, evaporator 1 4x yellow condenser: PFC protection.
EE = 15x heating, 11x yellow evaporator condenser: malfunction in the loading of EEPROM
PH = 11x cooling, 13x yellow evaporator condenser: High-voltage protection for PN.
PL = 21x heating, evaporator condenser 12x yellow: Low voltage PN protection.
U7 = 20x refrigeration evaporator: abnormal reversal of the 4-way valve.
P0 = minimum frequency compressor in test status.
P1 = nominal frequency compressor in test status.
P2 = maximum frequency compressor in test status.
P3 = intermediate frequency compressor in test status.
1x yellow Condenser compressor operates normally.
Red 8x Condenser temperature turn the unit on, normal hit.
EU = 6x cooling, heating 6x evaporator, condenser evaporator 11x red: upper limit of IPM drop in frequency temperature.
LU = 24x cooling, evaporator condenser 13x red: Frequency limit energy.
E2 = 2x operation, evaporator 3x yellow, condenser anti-freeze protection.
E3 = 3x operation, evaporator 9x red, condenser system blocked or leaking coolant.
E4 = 4x operation, yellow 7x evaporator, compressor condenser protected by high temperature
E5 = 5x operation, yellow 5x evaporator, condenser protection AC high current
E6 = 6x operation, green evaporator, condenser OFF: communication failure between pcs. Internal and external drive.
E8 = 8x operation, evaporator 6x yellow, condenser protection against high temperature
H4 = 4x heating. Evaporator 6x yellow capacitor protection against high temperature
H6 = 11x operation, evaporator without response from the indoor unit fan motor.
C5 = 15x operation, Evaporator: CIP jumper faulty or missing
LP = 19x operation, evaporator condenser 16x yellow: Internal and external drive does not match.
L3 = 23x operation, 14x red evaporator condenser malfunction in the external DC fan motor.
L9 = 20x operation, 9x yellow evaporator condenser: power protection.
F0 = 1x operation, 1x evaporator cooling, evaporator: collecting soda.
F1 = 1x cooling, evaporator: the problem of indoor sensor.
F2 = 2x cooling, evaporator: immersion sensor evaporator problem
F3 = 3x cooling, evaporator condenser 6x red: external environment sensor problem.
F4 = 4x cooling, 5x red evaporator condenser: immersion sensor condenser problem.
F5 = 5X cooling, 7x red evaporator condenser condenser temperature sensor problem.
F6 = 6x cooling, 3x red evaporator condenser: limit load on frequency drop.
F8 = 8x cooling, 1x red evaporator condenser: high current limit frequency drop.
F9 = 9x cooling, 2x red evaporator condenser: high temperature often fall outside air.
FH = 2x cooling, heating 2x evaporator, red evaporator 4x anti-freeze down frequency condenser.
H1 = 1x heating, 2x yellow evaporator condenser: Thawing
H3 = 3x heating, 8x yellow evaporator condenser: compressor overload protection.
H5 = 5x heating, evaporator 4x yellow Condenser protection IPM.9
H5 = 5x heating, 10x yellow evaporator condenser: very high temperature module.
HC = 6x heating, evaporator 1 4x yellow condenser: PFC protection.
EE = 15x heating, 11x yellow evaporator condenser: malfunction in the loading of EEPROM
PH = 11x cooling, 13x yellow evaporator condenser: High-voltage protection for PN.
PL = 21x heating, evaporator condenser 12x yellow: Low voltage PN protection.
U7 = 20x refrigeration evaporator: abnormal reversal of the 4-way valve.
P0 = minimum frequency compressor in test status.
P1 = nominal frequency compressor in test status.
P2 = maximum frequency compressor in test status.
P3 = intermediate frequency compressor in test status.
1x yellow Condenser compressor operates normally.
Red 8x Condenser temperature turn the unit on, normal hit.
EU = 6x cooling, heating 6x evaporator, condenser evaporator 11x red: upper limit of IPM drop in frequency temperature.
LU = 24x cooling, evaporator condenser 13x red: Frequency limit energy.
the indoor unit error code type Split Wall capacity unit of 7,000, 9,000 and 12,000 BTU hour.
Power on, Operation on, Timer flashes: room temperature sensor 1 blue.
Power on, Operation on, Timer flashes: temperature sensor input yellow coil 4.
Power on, Operation on, Timer flashes: intermediate coil temperature sensor -Red 3.
Power on, Operation on, flashes on Timer: temperature sensor coil output - black 2.
Power on, operation flashes, off Timer: defrost operation.
Power off, off operation, timer flashes: antifreeze protection.
Power off, operation flash, timer on operation mode of conflict.
Power flashes, operation flashes, blinks Timer: Communication failure.
Power flashes, operation off, Timer off: operation failure of the outdoor unit.
Códigos de erro do condicionador de ar Split GREE
Análise de códigos inverter e ON
OFF
E2 = 2x funcionamento, evaporador
3x amarelo, condensador proteção de anti-congelamento.
E3 = 3x funcionamento, evaporador
9x vermelho, condensador sistema bloqueado ou vazamento do refrigerante.
E4 = 4x funcionamento, evaporador
7x amarelo, condensador compressor protegido por alta temperatura
E5 = 5x funcionamento, evaporador 5x amarelo,
condensador proteção AC de alta corrente
E6 = 6x funcionamento, evaporador
verde, condensador em OFF: falha na comunicação entre unid. Interna e unidade
externa.
E8 = 8x funcionamento, evaporador
6x amarelo, condensador proteção contra alta temperatura
H4 = 4x aquecimento. Evaporador 6x
amarelo condensador proteção contra alta temperatura
H6 = 11x funcionamento, evaporador
sem resposta do motor de ventilação da unidade interna.
C5 = 15x funcionamento, evaporador:
jumper da CIP com problema ou faltante
LP = 19x funcionamento, evaporador
16x amarelo condensadora: unidade interna e externa não corresponde.
L3 = 23x funcionamento, evaporador 14x vermelho condensadora mau funcionamento
no motor de ventilação DC externo.
L9 = 20x funcionamento, evaporador
9x amarelo condensador: proteção de energia.
F0 = 1x funcionamento, evaporador
1x refrigeração, evaporador: coleta do refrigerante.
F1 = 1x refrigeração, evaporador:
problema no sensor de ambiente interno.
F2 = 2x refrigeração, evaporador:
sensor de imersão do evaporador com problema
F3 = 3x refrigeração, evaporador 6x
vermelho condensador: sensor ambiente externo com problema.
F4 = 4x refrigeração, evaporador 5x
vermelho condensador: sensor de imersão do condensador com problema.
F5 = 5x refrigeração, evaporador 7x
vermelho condensador sensor de temperatura do condensador com problema.
F6 = 6x refrigeração, evaporador 3x vermelho
condensador: limite de sobre carga queda de freqüência.
F8 = 8x refrigeração, evaporador 1x
vermelho condensador: limite de alta corrente queda de freqüência.
F9 = 9x refrigeração, evaporador 2x
vermelho condensador: alta temperatura do ar externo queda de freqüência.
FH = 2x refrigeração, evaporador 2x
aquecimento, evaporador 4x vermelho condensador anti-congelamento queda de
freqüência.
H1 = 1x aquecimento, evaporador 2x
amarelo condensador: descongelamento
H3 = 3x aquecimento, evaporador 8x
amarelo condensador: proteção da sobrecarga do compressor.
H5 = 5x aquecimento, evaporador 4x
amarelo condensador: proteção IPM.9
H5 = 5x aquecimento, evaporador 10x
amarelo condensador: modulo de temperatura muito alta.
HC = 6x aquecimento, evaporador 1
4x amarelo condensador: proteção PFC.
EE = 15x aquecimento, evaporador
11x amarelo condensador: mau funcionamento no carregamento do EEPROM
PH = 11x refrigeração, evaporador
13x amarelo condensador: proteção de
alta tensão para PN.
PL = 21x aquecimento, evaporador
12x amarelo condensador: proteção de baixa tensão do PN.
U7 = 20x refrigeração, evaporador:
reversão anormal da válvula de 4 vias.
P0 = compressor de freqüência
mínima no status de teste.
P1 = compressor de freqüência
nominal em status de teste.
P2 = compressor de freqüência
máxima em status de teste.
P3 = compressor de freqüência
intermediária no status de teste.
1x amarelo condensador: compressor
funciona normalmente.
8x vermelho condensador: a
temperatura liga a unidade e atingida normal.
EU = 6x refrigeração, evaporador 6x
aquecimento, evaporador 11x vermelho condensador: limite superior da
temperatura IPM queda na freqüência.
LU = 24x refrigeração, evaporador
13x vermelho condensadora: limite da freqüência energia.
Código de erros da unidade interna
tipo Split Wall unidade de capacidade de 7.000, 9.000 e 12.000 BTU hora.
Power on, Operação on, Timer pisca:
sensor de temperatura ambiente azul 1.
Power on, Operação on, Timer pisca:
sensor de temperatura da entrada da serpentina amarelo 4.
Power on, Operação on, Timer pisca:
sensor de temperatura intermediária serpentina
-vermelho 3.
Power on, Operação on, pisca Timer
on: sensor de temperatura da saída da
serpentina – preto 2.
Power on, operação pisca, Timer
off: operação de degelo.
Power off, operação off, timer
pisca: proteção anticongelamento.
Power off, operação pisca, timer
on: conflito de modo de operação.
Power pisca, operação pisca, Timer
pisca: falha de comunicação.
Power pisca, operação off, Timer
off: falha de operação da unidade externa.
Tipos e Capacidades térmicas dos condicionadores de ar da atualidade
|
AR SPLIT
Capacidade
7.500 BTUs/h
9.000 BTUs/h
12.000 BTUs/h
18.000 BTUs/h
24.000 BTUs/h
30.000 BTUs/h
|
SPLIT INVERTER
Capacidade
9.000 BTUs/h
12.000 BTUs/h
18.000 BTUs/h
24.000 BTUs/h
30.000 BTUs/h
|
AR JANELA
Capacidade
7.500 BTUs/h
10.500 BTUs/h
12.000 BTUs/h
18.000 BTUs/h
30.000 BTUs/h
|
|
SPLIT WINDOW
Capacidade
7.500 BTUs/h
9.000 BTUs/h
|
MULTIPLIST PODE SER BISPLIT E
TRISPLIT.
Capacidade da evaporadores geralmente são 9.000 BTUs/h
|
PISO TETO
Capacidade
18.000 BTUs/h
24.000 BTUs/h
30.000 BTUs/h
36.000 BTUs/h
48.000 BTUs/h
60.000 BTUs/h
80.000 BTUs/h
|
|
SPLIT CASSETE
Capacidade
18.000 BTUs/h
24.000 BTUs/h
30.000 BTUs/h
33.000 BTUs/h
36.000 BTUs/h
48.000 BTUs/h
60.000 BTUs/h
|
AR PORTÁTIL
Capacidade
10.500 BTUs/h
12.000 BTUs/h
|
SPLIT DUTO
Capacidade
24.000 BTUs/h
42.000 BTUs/h
48.000 BTUs/h
58.000 BTUs/h
|
Assinar:
Postagens (Atom)