What is the function of the voltmeter relay with electrolytic capacitor in an air conditioner?

The function of the voltimetric relay is to remove the starting (electrolytic) capacitor from the circuit. When feeding the coil of the voltmeter relay, an electromagnetic field is generated that acts the normally closed contact, causing the same to open, removing the starting capacitor, which is installed in series with voltmeter relay contact. Current compressors dispense starter capacitors. The need to use the voltmeter relay only occurs in older air conditioner. Over time the compressor finds it difficult to get into operation and, to facilitate starting, compensating for mechanical wear.

Qual a função do relé voltimétrico com capacitor eletrolítico, em um aparelho de ar condicionado?

A função do relé voltimétrico é retirar o capacitor de partida (eletrolítrico) do circuito. Ao alimentar a bobina do relé voltimétrico é gerado um campo eletromagnético que atua o contato normalmente fechado, fazendo o mesmo abrir, retirando o capacitor de partida, que se encontra instalado em série com contato do relé voltimétrico. Compressores atuais dispensam capacitores de partidas. A necessidade da utilização do relé voltimétrico ocorre somente em aparelho de ar condicionado mais antigos. Com o passar do tempo o compressor encontra dificuldade para entrar em funcionamento e, para facilitar a partida, compensando desgastes mecânicos.

How do I know if the compressor in a refrigerator is compressing?

In order to test the lack of compression of a compressor, the manometer must be installed on the low and high pressure sides (suction and discharge) of the system. If there is no compression, the suction pressure will be high to low discharge. The temperature of the discharge line will be lower than that normally encountered and the temperature of the compressor will be high. We recommend that you do not test the compressor out of the system. Taking the product to the workshop, analyzing the problem, passing the budget and performing the reoperation demonstrates concern for the safety and quality of services.

Como saber se o compressor de um refrigerador está comprimindo?

Para se testar a falta de compressão de um compressor, devem-se instalar manômetro nos lados de baixa e alta pressão (sucção e descarga) do sistema. Se não houver compressão, a pressão de sucção será alta a descarga baixa. A temperatura da linha de descarga será menor que a normalmente encontrada e a temperatura do compressor estará elevada. Recomendamos não testar o compressor fora do sistema. Levar o produto até a oficina, analisar o problema, passar o orçamento e executar a reoperação demonstra preocupação com a segurança e a qualidade dos serviços.

What is the operation of a PTC type relay of a hermetic compressor?

The PTC relay consists basically of a ceramic insert that acts as a bridge between the relay contacts. This material has the property of increasing its resistance when heated by the current passing through it. During startup, with current flowing to the starter coil, the resistor rapidly reaches a very high value, reducing the current in the starter coil until it is withdrawn from operation. Its use is recommended for freezers and domestic refrigerators, due to the time required for cooling between the operating cycles.

Como é o funcionamento de um relé tipo PTC de um compressor hermético?

O relé PTC é formado basicamente por uma pastilha de material cerâmico que atua como ponte entre os contatos do relé. Este material possui a propriedade de aumentar sua resistência quando aquecido pela corrente que passa através do mesmo. Durante a partida, com a corrente fluindo à bobina de partida, a resistência atinge rapidamente um valor muito alto, reduzindo a corrente na bobina de partida até retirá-la de operação. Seu uso é recomendado para freezers e refrigeradores domésticos, devido ao tempo necessário para resfriamento entre os ciclos de operação. 

How to find out the actual ohmic resistance of a winding of a hermetic compressor?

Measurement of the ohmic field resistance of auxiliary (starting) and mainly (running) coils must be made with the compressor switched off without the electrical components and at an ambient temperature stabilized for 12 hours at 25 ° C (resistance in the coils varies with room temperature : The higher the resistance reading obtained). Under these conditions, the resistance of the coils is measured directly at the airtight terminal of the compressor with an ohmmeter; For the auxiliary coil (starting) the measurement is made between the terminals C - S (Common - Start) of the hermetic terminal and for the main coil between the terminals C - R (Common - Run) with hermetic terminal. The specification of the resistance of the Sicom compressor coils at 25 ° C has a tolerance of plus or minus 7%. The resistance of the auxiliary coil is connected to the start of the compressor, not to its cooling capacity. A compressor with greater than the specified auxiliary coil resistance (eg, 8 to 10%) may cause a decrease in the starting torque of the compressor, thereby impairing its starting. If the coil resistance is out of specification, there may be a decrease in the rotation of the compressor and consequent loss of cooling capacity that can be reached by the compressor.