Electrical care in the installation of the inverter air conditioner with refrigerant R-410A

 • Incorrect connections of the electrical installation can cause burning of electrical parts.

• Be sure to use the positions specified for the wire clamps, according to the diagram that accompanies the product.

• Do not damage or scratch the conductor core and the internal insulation of the power and interconnect cables when stripping.

• Comply with the local code when extending the wire from the indoor unit to the outdoor unit. (wire size and wiring method, etc.)

• Use power and interconnect cables with specified thickness and type as well as specified protective devices.

• Use a switch that does not trigger shock waves.

• If the wiring is done incorrectly, it will cause fire or smoke.

• Prepare the source of use for the exclusive use of the air conditioner.

• This product can be connected to the main conductors. Connection to fixed wiring:

A switch or circuit breaker that disconnects all poles and has a separation between the contacts of at least 3mm must be incorporated into the fixed wiring.

Approved circuit breakers or switches must be used.

* (Usually a circuit breaker with a sensitivity of approximately 0.1 second or less and a capacity of approximately 30 mA is used).