Role of the remote control of the external air conditioner unit Split inverter

 Upon receiving the operating command signal (serial signal) from the internal control, the external unit performs its function.

• Inverter current detection and current release operation.

• Overload detection and prevention operation by the transistor module (Compressor stop function).

• The compressor and the external fan stop when the serial signal is off (when the serial signal does not reach the external control board due to signal system problems).

• Transfer of information about the operation (serial signal) from the outdoor unit to the indoor unit.

• Detection of external temperature and control of operation speed.

• Defrost control during heating operation (temperature measurement by external heat exchanger and control of the 4-way valve and external fan).