• Supply voltage: 110/220 Volts and 50/60 Hz automatic.
• Switching voltage of the support and pumping outputs: 5 amps at 220V maximum.
• Consumption: 1 Watt (Solar Control only).
• Measurement range from 0 to 100 ° C.
• Accuracy of +/- 0.3 ° C.
• Sensor Type: NTC.
• Number of sensors: three, with capsule and 2m cable.
• Standard real time clock 24h.
• 24 hour power outage system.
• Adjustment range for heating temperature control
auxiliary (set1): 10 to 99 ° C.
• Setting range for auxiliary heating temperature differential (difr) control: 1 to 15 ° C.
• Adjustment range for collector temperature control (set2): 10 to 99 ° C.
• Adjustment range for pool or thermal tank temperature control (set3): 10 to 99 ° C.
• Differential adjustment range for starting the pump (dion): 2 to 15 ° C.
• Differential adjustment range for pump shutdown (diof): 1 to 15 ° C.
• Timer with up to 7 programmable time events combined with thermostat function (auxiliary heating).